Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Medicine (Baltimore) ; 102(43): e35715, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37904390

RESUMEN

BACKGROUND: We aimed to compare the effect of manual hyperinflation with versus without positive end-expiratory pressure (PEEP) on dynamic compliance of the respiratory system in pediatric patients undergoing congenital heart surgery; to assess the safety of the technique in this population. METHODS: This was a randomized controlled trial conducted at the pediatric intensive care unit (PICU) of a tertiary-care hospital. Patients admitted to the PICU following cardiac surgery and receiving postoperative mechanical ventilation were randomized to the experimental or control group. Patients in the experimental group (n = 14) underwent manual hyperinflation with a PEEP valve set at 5 cm H2O, once daily, during the first 48 hours after surgery. Patients allocated to the control group (n = 16) underwent manual hyperinflation without PEEP, at the same time points. Lung mechanics was assessed before (T0) and 5 minutes (T5) after manual hyperinflation. The primary endpoint was dynamic compliance. Secondary outcomes included oxygen saturation index, duration of mechanical ventilation, length of stay, 28-day mortality and safety. RESULTS: Demographic and clinical characteristics were comparable in both groups. There was no significant difference in dynamic compliance between times in each group (Day 1: (mean) 0.78 vs 0.81 and 0.70 vs 0.77; Day 2: 0.85 vs 0.78 and 0.67 vs 0.68 mL/kg/cm H2O, in experimental and control groups, respectively; P > .05). Mean deltas of dynamic compliance were not significantly different between groups. The proportion of patients extubated <72 hours after surgery was similar in experimental and control groups (43% vs 50%, respectively; P = .73). Oxygen saturation index, length of stay, and 28-day mortality were not significantly different between groups. None of the patients had hemodynamic instability. CONCLUSIONS: Manual hyperinflation was safe and well tolerated in pediatric patients following surgery for congenital heart disease. No significant change in dynamic compliance of the respiratory system or in oxygenation was observed with the use of manual hyperinflation with or without PEEP in this population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Humanos , Niño , Respiración Artificial/métodos , Respiración con Presión Positiva/métodos , Pulmón , Cardiopatías Congénitas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...